Sim-100 Micro-spectrophotometer

The Simgen Sim-100 Micro Spectrophotometer is a new full wavelength micro-volume spectrophotometer that applies the surface tension properties of liquids with a sample volume of 0.5-2 μl. On the detection table, a fixed optical path is pulled out through the contact of the upper and lower arms to achieve rapid, micro, and high-concentration detection, and at the same time, there is no need for consumables such as quartz tubes and capillaries. The high-energy xenon light source provides full-spectrum detection from 190-840 nm and can be turned on and used at any time without the need for warm-up. The instrument is widely used to detect nucleic acids, proteins, cell solutions, microarray samples, and conventional full-wavelength scanning.

Sim-100 Micro-spectrophotometer

The Simgen Sim-100 Micro Spectrophotometer is a new full wavelength micro-volume spectrophotometer that applies the surface tension properties of liquids with a sample volume of 0.5-2 μl. On the detection table, a fixed optical path is pulled out through the contact of the upper and lower arms to achieve rapid, micro, and high-concentration detection, and at the same time, there is no need for consumables such as quartz tubes and capillaries. The high-energy xenon light source provides full-spectrum detection from 190-840 nm and can be turned on and used at any time without the need for warm-up. The instrument is widely used to detect nucleic acids, proteins, cell solutions, microarray samples, and conventional full-wavelength scanning.

Price List

Cat. No.  specification Price
Yes-100 1 unit contact us

Introduction

The Simgen Sim-100 Micro Spectrophotometer is a new full wavelength micro-volume spectrophotometer that applies the surface tension properties of liquids with a sample volume of 0.5-2 μl. On the detection table, a fixed optical path is pulled out through the contact of the upper and lower arms to achieve rapid, micro, and high-concentration detection, and at the same time, there is no need for consumables such as quartz tubes and capillaries. The high-energy xenon light source provides full-spectrum detection from 190-840 nm and can be turned on and used at any time without the need for warm-up. The instrument is widely used to detect nucleic acids, proteins, cell solutions, microarray samples, and conventional full-wavelength scanning.

Features

  • The sample volume is small, no dilution is required, and no cuvette is required
  • UV-Vis full wavelength scan (200-850 nm)
  • No need to preheat, directly open and test, fast speed, direct display of concentration value
  • The concentration range of the sample is 50 times that of a conventional UV-Vis spectrophotometer
  • Statistical software is simple and easy to master

Specifications:

Sample Volume Test Holes Pathlength Light source
1-2 μl 1 pc 1 mm (automatic to 0.05 mm) Xenon flash source
Detectors: Wavelength range: Wavelength accuracy: Wavelength Resolution:
3864 unit linear CCD array 200-850 nm 1 nm 3 nm(FWHM@Hg546 nm)
Absorbance accuracy: Absorbance accuracy: Absorbance range: Lower limit of detection (dsDNA):
0.003 Abs 1%(0.76 absorbance 350 nm) 0.02-75(Equivalent to 10 nm) 2 ng/μl
Test time: Instrument size (mm): Instrument Medium Weight(kg): Sample Holder Material:
< 5 seconds 200*170*300 1.35 Quartz fiber and non-lure steel
Power Adapter: Power consumption: Static Power Consumption: Software operating platform
12 V DC 12-18 watts 5 watts Windows/OS

Experimental data

Figure 1: The graph below shows the measured results of DNA concentration and purity.

Resources

Thesis

  1. Lou H, Li H, Wei T, et al. Stimulatory effects of oleci acid and fungal elicitor on betulinic acid production by submerged cultivation of medicinal mushroom Inonotus obliquus[J]. Journal of Fungi, 2021, 7(4): 266.